Welcome To b2b168.com, Join Free | Sign In
中文(简体) |
中文(繁體) |
Francés |Español |Deutsch |Pусский |
| No.8754912
![](http://i.b2b168.com/e/tag_pthy.gif)
- Product Categories
- Friendly Links
Information Name: | Supply humidifier, Tianjin - Tianjin high-pressure micro-mist humidifier |
Published: | 2012-03-16 |
Validity: | 365 |
Specifications: | M2 |
Quantity: | 100.00 |
Price Description: | |
Detailed Product Description: | The principle of high-pressure spray humidifier The high-pressure spray humidifier is through a special nozzle to spray water through the pressurized and atomized in the air (20 ~ 40μm), mist emitted particles and the flow of air, heat and moisture transfer and absorption of air in the heat, vaporized, the air humidity increases, air humidification processing. The high-pressure spray humidifier composed by two parts of the host, spray system. The host installation on the side panel of the air conditioning unit, spray systems, sprinklers and boom, mounted within the air conditioning unit. Conditions of use of high-pressure spray humidifier ● Ambient temperature: the humidifier host: 1 ℃ -40 ℃ spray system: 1 ℃ -80 ℃ ● Relative Humidity: 80% ● The wind velocity :0.5-3 .5 m / s (≥ 15 ° C) Water supply conditions: 0.1MPa-0.5MPa, clean tap water (4 ℃ -70 ° C) ● Power supply: single phase AC 220V ± 10%, 50Hz Shape structure to indicate high-pressure spray humidifier Conditions of use of high-pressure spray humidifier ● Ambient temperature: the humidifier host: 1 ℃ -40 ℃ spray system: 1 ℃ -80 ℃ ● Relative Humidity: 80% ● The wind velocity :0.5-3 .5 m / s (≥ 15 ° C) Water supply conditions: 0.1MPa-0.5MPa, clean tap water (4 ℃ -70 ° C) ● Power supply: single phase AC 220V ± 10%, 50Hz Technical Features 1, using imported Italian pump, stable operation, low noise, safe and reliable; 2, using a special ceramic nozzle, wear resistance, corrosion resistance, atomized fine particles (diameter 20 ~ 40μm), high efficiency humidification; 3, with anhydrous protection function. Water without water instantly perceived, and turn off the pump to prevent dry damaged. Water recovery, the machine automatically restored. 4, the pump motor stall protection function. Long-term disabled machine, in the next boot, can easily cause the motor to stall, the current is too large to burn. This function is to adequately protect the pump motor running reliability, internal current detection system to ensure that instantly start to protect the instant when the motor stalled. 5, nozzle clogging protection and alarm function. The nozzle of the nozzle diameter is generally less than 0.8mm, even with the water high precision filter can not guarantee long-term use may cause clogging of the nozzle. This feature can ensure that the nozzle clogging shut down pumps implement protection and alert the user to wash nozzle. Acceptable control of the humidity sensor is also acceptable to the building automation system ON / OFF humidity control signal, the remote automatic control of humidity. Installation of high-pressure spray humidifier Install high-pressure spray in the air conditioning unit should follow the first heated humidification principle, such a help to improve the humidification efficiency; 2, the humidifier water supply inlet must be installed a sophisticated water filter, in order to reduce the turbidity of the water, to prevent nozzle clogging; Local water quality is excellent, often in order to prevent long-term use in scale plug nozzle and heroin phenomenon, it is recommended nozzle blockage; 4, air conditioning units in the high-pressure spray humidifier must set file water board, to prevent non-vaporized droplets drift in the air to the motor or into the duct, affecting their life. File the water board to the water board of the wet film file, not only can effectively file water, and the second humidification, and improve the humidification efficiency; 5, the site must provide within 2 m of DN15 water pipe and 220V 50Hz single-phase three-pin socket, water and power need to be diverted to the distance humidifier installation location, and the shorter the distance the better. The installation of the spray system * Spray system installation is generally the reverse jet or vertical jet Tianjin Yi Cheng Fei Science and Technology Development Co., Ltd. Han Hongliang 15822908655 www.tj-ycf.com |
Admin>>>
You are the 8687 visitor
Copyright © GuangDong ICP No. 10089450, Tianjin Yi Cheng Fei Science and Technology Development Co., Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 8687 visitor
Copyright © GuangDong ICP No. 10089450, Tianjin Yi Cheng Fei Science and Technology Development Co., Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility